Features:
After the frequency conversion transformation of the air compressor, the
pressure always remains at the required set working pressure, which can be
reduced by 10% compared with that before the transformation. The energy consumed
during unloading operation is about 40% of that during loading and unloading,
which can save about 10% according to the average unloading time. The frequency
converter can make the motor start, load the current gently rise, without any
impact; The motor can be soft stop to avoid the harm caused by reverse current,
which is beneficial to extend the service life of the equipment. After adopting
the frequency conversion control system, the pressure of the gas in the air
supply pipeline can be monitored in real time, so that the pressure of the gas
in the air supply pipeline can be kept constant and the production efficiency
and product quality can be improved. The variable frequency starting current of
the air compressor is small, less than 2 times the rated current, and the
loading and unloading valve does not need repeated action. The variable
frequency air compressor automatically adjusts the motor speed according to the
gas consumption. The running frequency is low, the speed is slow, the bearing
wear is small, the service life of the equipment is extended, and the
maintenance workload is small. Frequency conversion provides energy according to
the requirement of gas consumption without too much energy loss. Motor operating
frequency is low, and mechanical rotation noise becomes smaller. As frequency
conversion is used to adjust motor speed, there is no repeated loading and
unloading, nor is frequent loading and unloading noise. Adopting frequency
converter drive system to save energy, reduce production cost, improve labor
productivity and product quality.
Product parameters:
Model/Specification | Q10FA | Q15FA | Q20FA | Q25FA | Q30FA | Q40FA | Q50FA | Q60FA | Q75FA |
Free Air Delivery/Discharge Pressure (m³/min) | 1.2/0.7 | 1.65/0.7 | 2.5/0.7 | 3.2/0.7 | 3.8/0.7 | 5.3/0.7 | 6.8/0.7 | 7.4/0.7 | 10.0/0.7 |
1.1/0.8 | 1.5/0.8 | 2.3/0.8 | 3.0/0.8 | 3.6/0.8 | 5.0/0.8 | 6.2/0.8 | 7.0/0.8 | 9.2/0.8 |
0.95/1.0 | 1.3/1.0 | 2.1/1.0 | 2.7/1.0 | 3.2/1.0 | 4.5/1.0 | 5.6/1.0 | 6.2/1.0 | 8.5/1.0 |
0.8/1.2 | 1.1/1.2 | 1.9/1.2 | 2.4/1.2 | 2.7/1.2 | 4.0/1.2 | 5.0/1.2 | 5.6/1.2 | 7.6/1.2 |
Ambient Temperature | ℃ | 一5~+45 |
Cooling Mode | Air-Cooling |
Discharge Temperature | ℃ | Air -Cooling:≤Environment Temp+15℃ |
Lubricant | Liter | 10 | 18 | 30 | 65 |
Noise | Db(A) | 66±2 | 68±2 | 72±2 |
Driven mode | Direct drive |
Electricity | 380V/50Hz |
Power | KW | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 |
Starting Mode | Variable freZuency starting |
Dimension | Length
mm | 800 | 1080 | 1080 | 1380 | 1380 | 1380 | 1500 | 1500 | 1900 |
Width
mm | 700 | 750 | 750 | 850 | 850 | 850 | 1100 | 1100 | 1250 |
Height
mm | 930 | 1000 | 1000 | 1160 | 1160 | 1160 | 1330 | 1330 | 1600 |
Weight | kg | 205 | 301 | 314 | 420 | 457 | 550 | 677 | 850 | 1600 |
Air Outlet Pipe Diameter | inch | Rp1/2 | Rp3/4 | Rp3/4 | Rp1 | Rp1 | Rp1 | R1,1/2 | R1,1/2 | Rp2 |
Model/Specification | Q100FA | Q120FA | Q150FA | Q175FA | Q200FA | Q250FA | Q300FA | Q350FA |
Free Air Delivery/Discharge Pressure
(m³/min) | 13.4/0.7 | 16.2/0.7 | 21/0.7 | 24.5/0.7 | 28.7/0.7 | 32/0.7 | 36/0.7 | 42/0.7 |
12.6/0.8 | 15.0/0.8 | 19.8/0.8 | 23.2/0.8 | 27.6/0.8 | 30.4/0.8 | 34.3/0.8 | 40.5/0.8 |
11.2/1.0 | 13.8/1.0 | 17.4/1.0 | 20.5/1.0 | 24.6/1.0 | 27.4/1.0 | 30.2/1.0 | 38.2/1.0 |
10.0/1.2 | 12.3/1.2 | 14.8/1.2 | 17.4/1.2 | 21.5/1.2 | 24.8/1.2 | 27.7/1.2 | 34.5/1.2 |
Ambient Temperature | ℃ | 一5~+45 |
Cooling Mode | Air-Cooling |
Discharge Temperature | ℃ | Air -Cooling:≤Environment Temp+15℃ |
Lubricant | Liter | 65 | 72 | 90 | 110 | 125 | 150 |
Noise | Db(A) | 76±2 | 82±2 | 86±2 |
Driven mode | Direct drive |
Electricity | 380V/50Hz |
Power | KW | 75 | 90 | 110 | 132 | 160 | 185 | 220 | 250 |
Starting Mode | Variable freZuency starting |
Dimension | Length
mm | 2000 | 2000 | 2300 | 2300 | 2500 | 3600 | 3600 | 3600 |
Width
mm | 1250 | 1250 | 1470 | 1470 | 1470 | 2100 | 2100 | 2100 |
Height
mm | 1680 | 1680 | 1840 | 1840 | 1840 | 2280 | 2280 | 2280 |
Weight | kg | 1760 | 1860 | 2600 | 2680 | 2800 | 3500 | 3600 | 3800 |
Air Outlet Pipe Diameter | inch | Rp2 | Rp2 | Rp2,1/2 | Rp2,1/2 | Rp2,1/2 | DN80 | DN100 | DN100 |